Bilge pump ratings vs real flow

The short answer

The GPH on a bilge pump's label is its open-flow rating: water moved with no lift and no discharge hose resistance. Installed, it moves much less. Rule's published figures for its Rule-Mate 1100 show 860 GPH at 3.35 ft of head and 550 GPH at 6.7 ft — half the label rating — and even those figures assume 13.6 V at the pump.

  • Rated GPH = open flow at 0 ft of head
  • Every foot of lift and every fitting reduces delivered flow
  • Published ratings assume a charging-level voltage (13.6 V for 12 V models)
  • Plan capacity from the flow at your actual head height

What the rating on the box means

Manufacturers rate bilge pumps by open flow — the volume moved per hour with the outlet unrestricted and no vertical lift. It is a useful way to compare pumps with each other, and a poor guide to what leaves the boat. Real installations lift water from the bilge to a through-hull above the waterline, through hose, fittings and often a check or anti-siphon arrangement.

What Rule's own data shows

Rule's instruction manual for its Rule-Mate automatic pumps (RM500 through RM2000) publishes flow at three head heights. Rule notes the figures are measured after a 10-hour break-in and at 13.6 V for 12 V models (27.2 V for 24 V models).

Rated flowAt 0 ft (0 kPa)At 3.35 ft / 1 m (10 kPa)At 6.7 ft / 2 m (20 kPa)Share of rating at 6.7 ft
500 GPH50036026052%
750 GPH75058037550%
1,100 GPH1,10086055050%
1,500 GPH1,5001,20068045%
2,000 GPH2,0001,6201,30065%
Practical noteThese figures are for the Rule-Mate generation covered by that manual. Rule has since introduced a redesigned RuleMate III range; confirm the published curve for the exact model you buy. The share-of-rating column is a Nautworthy calculation.

Voltage changes the answer too

The same manual shows how current rises with voltage — the RM1100 draws 3.3 A at 12.0 V and 5.0 A at 13.6 V, and specifies a 5 A fuse. A pump rated at 13.6 V will move less water on a resting battery at 12.4 V, and less again if long or undersized wiring drops the voltage further at the pump. Keep the wiring run short, size conductors for low voltage drop, and follow the pump maker's fuse rating.

Planning an installation

  • Measure the vertical lift from the pump to the discharge through-hull; read capacity at that head, not the label rating.
  • Use smooth-bore hose of the pump's outlet size and keep the run as short and straight as practical — every bend and fitting costs flow.
  • Keep wire connections above the highest water level; Rule's manual specifies butt connectors with marine-grade sealant.
  • Follow ABYC H-22 (Electric Bilge Pump Systems) and the pump maker's instructions for switching, fusing and discharge arrangement.
  • Remember that a bilge pump handles nuisance water. It is not a substitute for finding and fixing the leak.