White sailboat mast and rigging against a deep blue sky

Department

Electrical & Power

Inverter/chargers, lithium house banks and shore power — sized from the datasheet, not the brochure.

Start here

Size the DC side first. An inverter's continuous rating tells you what it can run; the battery bank's continuous-discharge and charge-current limits tell you whether it will. Most failed lithium upgrades pass the first check and fail the second.

Decision factors

What decides the right choice

Continuous AC load

Add the AC loads you will run at the same time, then allow headroom. Check the inverter's rating at engine-room temperatures, not just at 25 °C.

DC current

Inverter watts ÷ (battery volts × efficiency). A 2,400 W, 12 V inverter pulls roughly 215 A — cable, fuse and battery must all handle it.

Charge rate

A 120 A charger into batteries rated for 50 A each needs three in parallel, or a lower charge-current setting.

Shore power

Know whether your inlet is 30 A 120 V or 50 A 120/240 V. It decides which inverter/charger variant fits.